CCWHV - ST-10 BRITTLE COATING

  • MSDS: CCWHV
  • Manufacturer: STRESSCOAT INC
  • Product Name: ST-10 BRITTLE COATING
  • National Stock Number: 8010-00N036386
Product Identification

Product ID:ST-10 BRITTLE COATING
MSDS Date:03/27/1995
FSC:8010
NIIN:00N036386
MSDS Number: CCWHV

Responsible Party
STRESSCOAT INC
1334 NORTH BENSON AVE A
UPLAND, CA 91786
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 909-981-6990

Preparer: JOHN HALL

Cage: STRES

Contractor
STRESSCOAT INC
UPLAND, CA 91786 US

Telephone: 714-946-4977

Cage: STRES

Ingredients

CONTAIN RESIDUE OF MATERIAL. ALWAYS OBEY HAZARD

RTECS: 9999999ZZ


METHANE, DICHLORO-; (DICHLOROMETHANE) (SARA 313) (CERCLA)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 20-50%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM, A2

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


METHANE, BROMOCHLORO-; (CHLOROBROMOMETHANE) (CERCLA)

CAS: 74-97-5

RTECS: PA5250000

Fraction By Weight: 20-50%

OSHA PEL 200 PPM

ACGIH TLV: 200 PPM


ROSIN SOAP

Fraction By Weight: 10-15%

OSHA PEL N/K

ACGIH TLV: N/K


CAUSE SYSTEMIC EFTS, DECISION OF WHETHER TO INDUCE

RTECS: 9999999ZZ


PERFORMED, SUGGEST ENDOTRACHEAL &/OR ESOPHAGEAL

RTECS: 9999999ZZ


WHEN CONSIDERING EMPTYING STOM. IF BURN IS PRESENT,

RTECS: 9999999ZZ


INCR "MYOCARDIAL IRRITABILITY". DO NOT ADMIN

RTECS: 9999999ZZ


ANTIDOTE. SUPPORTIVE CARE. TREATMENT BASED ON

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCD SENSIT
OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE SIMILAR
EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAININ G USES IN HUMANS
ACUTELY/CHRONICALLY EXPOS TO CHLOROCARBONS . ACUTE:INHAL:EXPOS MAY
CAUSE DROW & (EFTS OF OVEREXP)
Explanation of Carcinogenicity:DICHLOROMETHANE:IARC MONOGRAPHS, SUPP,
VOL 7, PG 194, 1987:GROUP 2B. NTP 7TH ANNUAL RPT ON CARCINS, 1994:
(SUPP DATA)
Effects of Overexposure:HLTH HAZS:LOSS OF COORD. AT HIGH CONCS MAY
CAUSE HDCH, NAUS & VOMIT. EYE CONT:CAUSES PAIN & MOD IRRIT & POSS
REVERSIBLE CORNEAL INJURY. SKIN CONT:SHORT EXPOS MAY CAUSE IRRIT.
BRIEF CONT MAY DRY & DISC OLOR. PRLNG/RPTD CONT MAY IRRIT, CAUSING
DERM. MAY CAUSE MORE SEV RESPONSE IF CONFINED, EVEN BURN.
INGEST:CAUSES(SUPDAT)
Medical Cond Aggravated by Exposure:PERSONS W/ANGINE OR HEART DISEASE
OR THOSE WHO ARE HEAVY DRINKERS OR SMOKERS SHOULD NOT BE EXPOSED TO
THIS PRODUCT.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE MOUTH-TO-MOUTH
RESUSCITATION. IF BRTHG IS DFCLT, GIVE OXYG. CALL MD. EYE:IMMED
FLUSH W/LOTS OF RUNNING WATER FOR @ LST 15 MIN, LIFTING LIDS OCCAS.
GET IMM ED MED ATTN. SKIN:CALL MD IF IRRIT PERSISTS. WASH CLTHG
BEFORE REUSE. DESTROY CONTAM CLTHG. INGEST:DO NOT INDUCE VOMIT.
CALL MD &/OR TRANSPORT TO EMER FACILITY IMMED. NOTE TO MD:BECAUSE
RAPID (SUPDAT)

Fire Fighting

Flash Point:NONE
Extinguishing Media:THIS MATERIAL IS NOT COMBUSTIBLE. USE EXTINGUISHING
MEDIA SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA &
FULL PROTECTIVE EQUIPMENT . CAN DECOMPOSE TO TOXIC PRODUCTS IN A
FIRE.
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:AVOID HEAVY CONCENTRATION OF VAPORS. WEAR
APPROPRIATE PROTECTIVE EQUIPMENT, AND USE SUITABLE CHEMICAL SPILL
EQUIPMENT TO CONTAIN AND CLEAN-UP SPILL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY, WELL VENTED PLACE
AWAY FROM INCOMPAT MATLS. VENT CNTNR FREQUENTLY TO RELIEVE PRESS.
KEEP CNTNR TIGHTLY CLSD WHEN NOT IN USE.
Other Precautions:NO SMOKING IN AREA OF ARC WELDING, OPEN FLAMES/HOT
SURFS. HEAT &/OR UV RADIA MAY CAUSE FORM OF HCL &/OR PHOSGENE .
KEEP AWAY FROM FOOD STUFFS. DO NOT CUT, GRIND, WELD/DRILL ON/NEAR
CNTNR. BE CAU TIOUS OF EMPTY CNTNRS WHICH MAY (ING 9)

Exposure Controls

Respiratory Protection:NIOSH APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR REQUIRED IN ABSENCE OF PROPER ENVIRONMENTAL CONTROL. FOR
EMERGENCIES, A NIOSH APPROVED POSITIVE PRESSURE, SELF-CONTAINED
BREATHING APPARATUS IS RECOMM ENDED.
Ventilation:LOCAL MECHANICAL EXHAUST VENTILATION CAPABLE OF MAINTAINING
EMISSIONS AT THE POINT OF USE BELOW THE PEL.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
SHOWER . CLEAN, BODY COVERING CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLAN OF CARCIN:ANTIC TO BE CARCIN. ANIMAL:LUNGS, THORAX, ENDOCRINE
SYS. EFTS OF OVEREXP:ABDOM PAIN & POSS ASPIR PNEUM IF VOMITED.
CHRONIC:RPTD EXCESSIVE EXPOS TO HIGH AMTS MAY CAUSE LIVER, KIDNEY &
TESTICULAR INJURY; MAY CAUSE CARBOXYHEMOGLOBINEMIA. FIRST AID
PROC:ABSORPTION MAY OCCUR THRU LUNGS IF ASPIR & (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:100F,38C
Vapor Pres:4.40 @100F
Vapor Density:3
Spec Gravity:>1.4 (H*2O=1)
Evaporation Rate & Reference:1-4 (ETHER=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR, AMBER LIQUID; SWEET ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
ALUMINUM, MAGNESIUM AND ZINC UNLESS INHIBITED. ALKALIS, OXIDIZING
MATERIALS, WATER AND MOIST AIR.
Stability Condition to Avoid:OPEN FLAMES, WELDING ARCS, OR OTHER HIGH
TEMPERATURE SOURCES WHICH MAY INDUCE THERMAL DECOMPOSITION.
Hazardous Decomposition Products:MAY LIBERATE CARBON MONOXIDE, CARBON
DIOXIDE, HYDROGEN CHLORIDE, CHLORINE OR PHOSGENE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL FEDERAL, STATE
AND LOCAL REGULATIONS. RCRA INFO:HAZARDOUS WASTE:F001, F003, F005.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.